Connect Modbus RTU Slaves to DeviceNet Slaves

Easily Connect up to 32 Modbus RTU Slaves to up to 32 DeviceNet Slaves

SKU: 460MMDM

460MMDM

$NZD 1,339.40 - $NZD 1,360.87

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Move Modbus RTU Slave Data to DeviceNet Slaves
The 460MMDM moves registers and coils between up to 32 Modbus RTU Slaves and a network of up to 32 DeviceNet Slaves. It’s the perfect tool to get your Modbus RTU Slave data connected to your DeviceNet Slave devices.

How Do I Use the 460MMDM in My Application?
For Most applications the mapping is very straight forward. Modbus register and coil data is mapped to the DeviceNet Slave devices as DeviceNet data. DeviceNet data is mapped directly to your Modbus RTU Slaves as Modbus RTU data. Up to 125 registers of data can be transferred from your Modbus RTU Slave devices. No other deep understanding of either protocol is required to configure the gateway.

It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?
The 460MMDM provides an option to connect your Modbus RTU Slave devices with your DeviceNet Slave devices. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus RTU Master Features

Modbus Operation Modes: Modbus RTU Master
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Slave Devices: 32
Number Read/Write Scan Lines per RTU Slave Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

DeviceNet Master Features

DeviceNet Operation Modes: UCMM Client, Group 2 Client, Group 2 only Client
Implicit Message Support: Polled only, Assembly Object
Maximum DeviceNet Slave Devices: 32
Data per Slave: 0-400 Bytes in each direction
Supported Data Types: BIT8, BIT16, BIT32, INT8, INT16, INT32, INT64, UINT8, UINT16, UINT32, UINT64, Float, Double

Gateway Security
You can configure up to nine different users with access to diagnostic and configuration screens.

Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.

460MMDM-N34
DATASHEET  USERGUIDE