Product Description

Get Your BACnet/IP Servers Connected Directly to Your DeviceNet Master
The 460DSBC moves data between up to 32 BACnet/IP Servers and a DeviceNet Master. With the 460DSBC you are making a direct connection between DeviceNet data and BACnet/IP Binary and Analog objects.

How Do You Map the Data?
Up to 240 bytes of DeviceNet data will be mapped to your BACnet/IP Servers as BACnet/IP data. Data will be assigned a type of BIT8, BIT16, BIT32, INT8, INT16, INT32, INT64, UINT8, UINT16, UINT32, UINT64, Float, or Double and be mapped into your BACnet/IP Building Automation System as Binary and Analog BACnet/IP objects. When writing from your BACnet/IP Servers to your DeviceNet Master, Analog and Binary BACnet/IP objects will be viewed as DeviceNet data.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
The 460DSBC provides an option to access BACnet/IP Server data in your DeviceNet Master without having to upgrade your established system. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

DeviceNet Slave Features

DeviceNet Operation Modes: DeviceNet Slave
Supported Data Types: Int8, int16, int32, int64, uint8, uint16, uint32, uint61, float, double float, binary8, binary16, binary32
Maximum Connections: 1
Maximum Input Size: 240 Bytes in up to 15 Data Groups
Maximum Output Size: 240 Bytes in up to 15 Data Groups

BACnet/IP Client Features

BACnet/IP Operation Modes: BACnet/IP Client
Supported Object Types: Device, BI/BO/BV, AI/AO/AV, MI/MO/MV, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads and 100 writes
Scan Line Support: Up to 128 Objects

Gateway Security
You can configure up to nine different users with access to diagnostic and configuration screens.

Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.